Determinación del aparato

Lista de control nº 7: Depósitos de doble pared y tuberías

1 through 8 essential for determining unit

1    Tanks: weight (kg); capacity (kg); maximum permissible pressure (bar); with/without 
      thermal insulation.
2    Pipes: length, ratio of cross-sections, with/without thermal insulation.
3    Volume of heat transfer fluid.
4    Temperature range.
5    Heat-up time (h).
6    Quantity of heat to be added or dissipated (x kW at consumer temperature y °C) or 
      material processing rate (kg/h).
7    Processing material.
8    Operating voltage (V/Hz), 3 PE.
9    Pump capacity (x l/min at y bar) or permissible temperature drop across the consumer (°C)
      and graph of pressure drop (bar) as a function of flow rate (l/min).
10  Control mode: heat transfer fluid or consumer: position and type of sensor (Pt100, J, K, T or N).
11  Cooling water mains: pressure and temperature range.
12  Accessories (hoses, coupling etc.): see "Regloplas Temperature Control Technology", section
      "Accessories".
13  For optional features, see «Regloplas – Temperature Control by Means of Fluid Media,
      5th edition», page 17, section 8.
14  See also Checklist 1 for additional information pertaining to problem, as well as Checklists 9 and 10.